Mitigating Fire-Induced Degradation in Concrete through Carbon Fiber Incorporation: An Experimental and Statistical Study

Authors

  • Wisam Abdulkadhim Hussein ORCID Department of Ceramic and Building Materials Engineering, College of Materials Engineering, University of Babylon, Hillah 51002, Iraq
  • Manar Hamid Jasim ORCID Babylon Polytechnic College, Al-Furat Al-Awsat Technical University, Najaf 54001, Iraq
  • Waleed Muwafaq Al-Aloosi Department of Medical Devices Engineering Technologies, College of Engineering Technology, University of Al-Maarif, Ramadi 31001, Iraq
  • Mohammed S. Radhi Department of Ceramic and Building Materials Engineering, College of Materials Engineering, University of Babylon, Hillah 51002, Iraq
  • Zainab Al-Khafaji Email ORCID Department of Civil Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia; Scientific Research Center, Al-Ayen Iraqi University, Nasiriyah 64001, Iraq
  • Mayadah Falah Civil Engineering Department, College of Engineering and Engineering Techniques, Al-Mustaqbal University, Hillah 51001, Iraq

DOI:

https://doi.org/10.30564/jbms.v8i4.116000
Received: 28 September 2025 | Revised: 23 October 2025 | Accepted: 23 September 2026 | Published Online: 23 November 2026

Abstract

High temperatures can cause severe damage to the load-bearing capacity and internal integrity of concrete. The residual performance of 1:2:4 concrete with carbon fibers based on polyacrylonitrile at 0%, 1% and 2% of the cement mass was investigated in this work. 36 100-mm cube specimens were cured for 28 days and exposed for 24 h to nominal temperatures of 25, 250, 500 and 750 °C. Residual compressive strength and direct-transmission ultrasonic pulse velocity (UPV) were tested after cooling. Differences among the 12 treatment groups were estimated using one-way analysis of variance (ANOVA) and Tukey’s honestly significant difference (HSD) test. The compressive strength decreased with the increase in temperature, while the residual strength increased with the addition of carbon fiber. The control, 1% and 2% fiber mixes showed strengths of 7, 10 and 11 MPa, respectively, at 500 °C with 40.0%, 55.6% and 55.0% retention of the ambient temperature strengths. The 2% fiber mix was 57.1% stronger than the control. The residual strength at 750 °C was 5 MPa (25.0% retention), which is double the control strength of 2.5 MPa (14.3% retention). Control-mixture UPV dropped from 4.54 km/s (25 °C) to 3.30 km/s (750 °C). The velocity of the 500 °C fiber mixtures was 4.10 km/s, and for the control, 3.80 km/s. The ANOVA analysis showed that the treatment groups were significantly different from each other (F = 1,114.96, p < 0.0001). The highest residual strength of the three conditions tested was observed for the 2 % carbon fiber.

Keywords:

Concrete, Carbon Fibers, Non-Polymer Fibers, Fire Exposure

References

[1] Muthukumarana, T.V., Arachchi, M.A.V.H.M., Somarathna, H.M.C.C., et al., 2023. A review on the variation of mechanical properties of carbon fibre-reinforced concrete. Construction and Building Materials. 366, 130173. DOI: https://doi.org/10.1016/j.conbuildmat.2022.130173

[2] Clarke, T., Ghiji, M., Fragomeni, S., et al., 2023. Mechanical properties of macro synthetic fiber reinforced concrete at elevated temperatures: A systematic review and meta-analysis. Structural Concrete. 24(1), 1244–1270. DOI: https://doi.org/10.1002/suco.202100918

[3] Al-Baghdadi, H.M., Mahan, H.M., Shubbar, A.A.F., et al., 2022. Studying the impact of imposed actual loads on the non-destructive test results for evaluating the compressive strength and other properties of concrete. International Review of Civil Engineering. 13(3), 226–233. DOI: https://doi.org/10.15866/irece.v13i3.20880

[4] Hamad, M.A., Nasr, M., Shubbar, A., et al., 2021. Production of ultra-high-performance concrete with low energy consumption and carbon footprint using supplementary cementitious materials instead of silica fume: A review. Energies. 14(24), 8291. DOI: https://doi.org/10.3390/en14248291

[5] Tuama, W.K., Kadhum, M.M., Alwash, N.A., et al., 2020. RPC effect of crude oil products on the mechanical characteristics of reactive-powder and normal-strength concrete. Periodica Polytechnica Civil Engineering. 64(2), 422–429. DOI: https://doi.org/10.3311/PPci.15580

[6] Marshdi, Q.S.R., Dakhil, A.J., Al-Khafaji, Z., 2024. Investigation of strength and durability performance of concrete with varying crude oil waste ratios. Research on Engineering Structures & Materials. 10(4), 1505–1521. DOI: https://doi.org/10.17515/resm2024.122me1211rs

[7] Alhamad, A., Yehia, S., Lublóy, É., et al., 2022. Performance of different concrete types exposed to elevated temperatures: A review. Materials. 15(14), 5032. DOI: https://doi.org/10.3390/ma15145032

[8] Abdullah, A.F., Abdul-Rahman, M.B.A.D., Al-Attar, A.A., 2024. A review on geopolymer concrete behaviour under elevated temperature influence. Journal of Sustainability Science and Management. 19(12), 239–259. DOI: https://doi.org/10.46754/jssm.2024.12.014

[9] Shahraki, M., Hua, N., Elhami-Khorasani, N., et al., 2023. Residual compressive strength of concrete after exposure to high temperatures: A review and probabilistic models. Fire Safety Journal. 135, 103698. DOI: https://doi.org/10.1016/j.firesaf.2022.103698

[10] Zhang, T., Zhang, M., Shen, Y., et al., 2022. Mitigating the damage of ultra-high performance concrete at elevated temperatures using synergistic flame-retardant polymer fibres. Cement and Concrete Research. 158, 106835. DOI: https://doi.org/10.1016/j.cemconres.2022.106835

[11] Adamu, M., Ibrahim, Y.E., Alanazi, H., 2022. Evaluating the influence of elevated temperature on compressive strength of date-palm-fiber-reinforced concrete using response surface methodology. Materials. 15(22), 8129. DOI: https://doi.org/10.3390/ma15228129

[12] Li, Y., Liu, Z., Jiang, J., 2024. Microstructure and macroscopic properties of low-carbon concrete subjected to elevated temperature: State-of-the-art review. Journal of Building Engineering. 86, 108731. DOI: https://doi.org/10.1016/j.jobe.2024.108731

[13] Amran, M., Huang, S.-S., Onaizi, A.M., et al., 2022. Fire spalling behavior of high-strength concrete: A critical review. Construction and Building Materials. 341, 127902. DOI: https://doi.org/10.1016/j.conbuildmat.2022.127902

[14] Gong, F., Jiang, X., Gamil, Y., et al., 2023. An overview on spalling behavior, mechanism, residual strength and microstructure of fiber reinforced concrete under high temperatures. Frontiers in Materials. 10, 1258195. DOI: https://doi.org/10.3389/fmats.2023.1258195

[15] Ali, A.Y.F., Ahmed, S.A., Youssef, P., et al., 2025. Fire performance and spalling mitigation in high-strength and EPS-modified mortars under transient thermal exposure. Scientific Reports. 15, 32497. DOI: https://doi.org/10.1038/s41598-025-17637-3

[16] Hamidi, F., Carré, H., Hamami, A.E.A., et al., 2023. Critical review of the use of fiber-reinforced concrete against spalling. Fire Safety Journal. 141, 103988. DOI: https://doi.org/10.1016/j.firesaf.2023.103988

[17] Ning, X., Li, J., Li, Y., 2022. An explorative study into the influence of different fibers on the spalling resistance and mechanical properties of self-compacting concrete after exposure to elevated temperatures. Applied Sciences. 12(24), 12779. DOI: https://doi.org/10.3390/app122412779

[18] Qin, D., Gao, P.K., Aslam, F., et al., 2022. A comprehensive review on fire damage assessment of reinforced concrete structures. Case Studies in Construction Materials. 16, e00843. DOI: https://doi.org/10.1016/j.cscm.2021.e00843

[19] Wang, H., Lyu, H., Liu, T., et al., 2022. Effect of post-fire curing on compressive strength of ultra-high performance concrete and mortar. Construction and Building Materials. 346, 128447. DOI: https://doi.org/10.1016/j.conbuildmat.2022.128447

[20] Sajid, H.U., Kiran, R., 2024. Effect of fiber reinforcement, mineral admixtures, and air entrainment on the fire performance of concrete in bridges: A review. Construction and Building Materials. 430, 136420. DOI: https://doi.org/10.1016/j.conbuildmat.2024.136420

[21] Carlton, A., Guo, Q., Ma, S., et al., 2022. Experimental assessment of explosive spalling in normal weight concrete panels under high intensity thermal exposure. Fire Safety Journal. 134, 103677. DOI: https://doi.org/10.1016/j.firesaf.2022.103677

[22] Khaleel, O.R., Al Wahaibi, M.M.S., Abed, M.J., et al., 2021. Performance of carbon fibre concrete subjected to fire. Materials Today: Proceedings. 42, 1160–1165. DOI: https://doi.org/10.1016/j.matpr.2020.12.530

[23] Moosaei, H.R., Zareei, A.R., Salemi, N., 2022. Elevated temperature performance of concrete reinforced with steel, glass, and polypropylene fibers and fire-proofed with coating. International Journal of Engineering, Transactions B: Applications. 35(5), 917–930. DOI: https://doi.org/10.5829/IJE.2022.35.05B.08

[24] Alves, A.J.G., 2008. Fire Behavior of Fiber Reinforced Concrete [Master’s Thesis]. University of Coimbra: Coimbra, Portugal. (in Portuguese)

[25] Mahasneh, B.Z., 2005. The effect of addition of fiber reinforcement on fire resistant composite concrete material. Journal of Applied Sciences. 5(2), 373–379. DOI: https://doi.org/10.3923/jas.2005.373.379

[26] Yoshitake, I., Baba, K., Ito, T., et al., 2005. Behavior of fiber reinforced concrete under fire temperature. In Proceedings of the International RILEM Workshop on High Performance Fiber Reinforced Cementitious Composites in Structural Applications, Honolulu, HI, USA, 23–26 May 2005.

[27] Zeng, Y., Zhou, X., Tang, A., et al., 2020. Mechanical properties of chopped basalt fiber-reinforced lightweight aggregate concrete and chopped polyacrylonitrile fiber reinforced lightweight aggregate concrete. Materials. 13(7), 1715. DOI: https://doi.org/10.3390/ma13071715

[28] Çavdar, A., 2012. A study on the effects of high temperature on mechanical properties of fiber reinforced cementitious composites. Composites Part B: Engineering. 43(5), 2452–2463. DOI: https://doi.org/10.1016/j.compositesb.2011.10.005

[29] Novák, J., Kohoutková, A., 2017. Fibre reinforced concrete exposed to elevated temperature. IOP Conference Series: Materials Science and Engineering. 246, 012045. DOI: https://doi.org/10.1088/1757-899X/246/1/012045

[30] Guo, Z., Zhuang, C., Li, Z., et al., 2021. Mechanical properties of carbon fiber reinforced concrete (CFRC) after exposure to high temperatures. Composite Structures. 256, 113072. DOI: https://doi.org/10.1016/j.compstruct.2020.113072

[31] Poon, C.S., Shui, Z.H., Lam, L., 2004. Compressive behavior of fiber reinforced high-performance concrete subjected to elevated temperatures. Cement and Concrete Research. 34(12), 2215–2222. DOI: https://doi.org/10.1016/j.cemconres.2004.02.011

[32] IQS No. 5/1984. 1984. Specification for Portland Cement. (in Arabic)

[33] IQS No. 45/1984. 1984. Aggregates from Natural Sources for Concrete and Building Construction. (in Arabic)

[34] ASTM C33-03. 2003. Standard Specification for Concrete Aggregates. Available from: https://store.astm.org/c0033-03.html

[35] BS EN 12390-3:2009. 2009. Testing Hardened Concrete: Compressive Strength of Test Specimens. Available from: https://knowledge.bsigroup.com/products/testing-hardened-concrete-compressive-strength-of-test-specimens-2

[36] ASTM C597-22. 2022. Standard Test Method for Ultrasonic Pulse Velocity through Concrete. Available from: https://store.astm.org/c0597-22.html

[37] Poon, C.-S., Azhar, S., Anson, M., et al., 2001. Comparison of the strength and durability performance of normal- and high-strength pozzolanic concretes at elevated temperatures. Cement and Concrete Research. 31(9), 1291–1300. DOI: https://doi.org/10.1016/S0008-8846(01)00580-4

[38] Das, T.K., Ghosh, P., Das, N.C., 2019. Preparation, development, outcomes, and application versatility of carbon fiber-based polymer composites: A review. Advanced Composites and Hybrid Materials. 2, 214–233. DOI: https://doi.org/10.1007/s42114-018-0072-z

[39] Mindeguia, J.-C., Pimienta, P., Carré, H., et al., 2013. Experimental analysis of concrete spalling due to fire exposure. European Journal of Environmental and Civil Engineering. 17(6), 453–466. DOI: https://doi.org/10.1080/19648189.2013.786245

[40] Patchen, A., Young, S., Penumadu, D., 2023. An investigation of mechanical properties of recycled carbon fiber reinforced ultra-high-performance concrete. Materials. 16(1), 314. DOI: https://doi.org/10.3390/ma16010314

[41] He, F., Biolzi, L., Carvelli, V., 2023. Effects of elevated temperature and water re-curing on the compression behavior of hybrid fiber reinforced concrete. Journal of Building Engineering. 67, 106034. DOI: https://doi.org/10.1016/j.jobe.2023.106034