Load-Deformation Behaviour of Roof Truss System Made with Cold-Formed Steel Hollow Rectangular Section

Authors

  • Mohd Syahrul Hisyam Mohd Sani

    Faculty of Civil Engineering, Universiti Teknologi MARA (UiTM) Pahang Branch, Bandar Jengka 26400, Pahang, Malaysia

  • Cher Siang Tan

    Faculty of Civil Engineering, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia

  • Fadhluhartini Muftah

    Faculty of Civil Engineering, Universiti Teknologi MARA (UiTM) Pahang Branch, Bandar Jengka 26400, Pahang, Malaysia

DOI:

https://doi.org/10.30564/jbms.v8i3.13582
Received: 1 June 2026 | Revised: 22 June 2026 | Accepted: 14 July 2026 | Published Online: 26 August 2026

Abstract

The swift advancement of modern construction has established cold-formed steel (CFS) as a prominent structural option owing to its high strength-to-weight ratio and lightweight properties. However, CFS in open sections such as channel and zee sections is heavily restricted by susceptibility to premature instabilities such as local, distortional, and lateral-torsional buckling. The study examines the structural performance, especially the load-deformation behaviour of closed structural sections, to address and resolve these deficiencies and limitations. The main objective of the study is to experimentally determine the load-deformation behaviour of a full-scale roof truss system fabricated from a CFS hollow rectangular section and to compare it with that of a CFS channel section. A full-scale roof truss measuring 4,900 mm in span and 1,100 mm in height was constructed in a Howe configuration type and assembled using 6 mm self-drilling screws. Static vertical load experimental activity was conducted utilising a 100 kN load cell, a hydraulic jack, five linear variable deformation transducers (LVDTs), and seven strain gauges linked to a data logger to record ultimate load capacity, deformation and localised strain actions. The experimental results indicated that the CFS hollow outperforms the CFS channel section, attaining a 52.42% increase in ultimate load capacity and a 21.66% decrease in vertical mid-span deformation. The CFS channel had premature local and distortional buckling at its top chords, but the CFS hollow successfully mitigated early geometric instabilities. Ultimately, the study concludes that CFS hollow serves as a highly efficient, stiff and structurally stable system that is ideal for lightweight and sustainable long-span roofing applications.

Keywords:

Load-Deformation Behaviour; Roof Truss System; Cold-Formed Steel; Hollow Rectangular Section; Channel Section

References

[1] Li, H., Shi, Y., Lu, W., et al., 2026. Flexural behavior of CFS trusses with strengthened joints. Thin-Walled Structures. 220, 114393. DOI: https://doi.org/10.1016/j.tws.2025.114393

[2] Li, H., Shi, Y., Peng, X., et al., 2025. Flexural behavior of parallel chord cold-formed steel trusses under serviceability limit states. Thin-Walled Structures. 215, 113568. DOI: https://doi.org/10.1016/j.tws.2025.113568

[3] Mahmoud, M.E., El-Sisi, A., Elbelbisi, A., et al., 2026. Effect of end-bearing connection configuration on static response of full-scale CFS trusses. Journal of Constructional Steel Research. 236, 109988. DOI: https://doi.org/10.1016/j.jcsr.2025.109988

[4] Mathieson, C., Clifton, G.C., Lim, J.B.P., 2016. Novel pin-jointed connection for cold-formed steel trusses. Journal of Constructional Steel Research. 116, 173–182. DOI: https://doi.org/10.1016/j.jcsr.2015.08.009

[5] Freitas, C.A.S., Yu, C., Nalla, S.K., 2026. Innovative continuous diagonal with stamped connections for cold-formed steel space trusses. Journal of Constructional Steel Research. 237, 110080. DOI: https://doi.org/10.1016/j.jcsr.2025.110080

[6] Freitas, C.A.S., Yu, C., Shahi, U., et al., 2025. Experimental and numerical study of a CFS truss with a stamped diagonal. Thin-Walled Structures. 217, 113870. DOI: https://doi.org/10.1016/j.tws.2025.113870

[7] Hussein, A.B., Papp, F., 2023. State-of-the-art: Integrating fastener technology and design guidelines for enhanced performance of cold-formed steel sections. Buildings. 13(9), 2338. DOI: https://doi.org/10.3390/buildings13092338

[8] Bondok, D.H., Salim, H.A., 2017. Failure capacities of cold-formed steel roof trusses end-connections. Thin-Walled Structures. 121, 57–66. DOI: https://doi.org/10.1016/j.tws.2017.09.026

[9] Gordziej-Zagórowska, M., Urbańska-Galewska, E., Deniziak, P., 2021. Analysis of failure mechanism in joints with positive eccentricity in CFS truss. Materials. 14(22), 6986. DOI: https://doi.org/10.3390/ma14226986

[10] Sam, V.S., Nammalvar, A., Andrushia, D., et al., 2024. Flexural behavior of galvanized iron based cold-formed steel back-to-back built-up beams at elevated temperatures. Buildings. 14(8), 2456. DOI: https://doi.org/10.3390/buildings14082456

[11] Wang, W., Roy, K., Rezaeian, H., et al., 2026. Structural behaviour of cold-formed steel trusses incorporating built-up section chords. Thin-Walled Structures. 218, 114054. DOI: https://doi.org/10.1016/j.tws.2025.114054

[12] Elsisi, A., Mahmoud, M.E., Salter, R., et al., 2026. Extreme static and blast performance of CFS roof trusses with symmetric profiles. Journal of Constructional Steel Research. 238, 110218. DOI: https://doi.org/10.1016/j.jcsr.2025.110218

[13] He, Z., Zhang, Y., Zhou, X., et al., 2024. Post-buckling behavior and DSM design of cold-formed steel lipped channel columns experiencing local-distortional-global interaction. Structures. 67, 106945. DOI: https://doi.org/10.1016/j.istruc.2024.106945

[14] Ma, J.-L., Chan, T.-M., Young, B., 2017. Tests on high-strength steel hollow sections: A review. Proceedings of the Institution of Civil Engineers—Structures and Buildings. 170(9), 621–630. DOI: https://doi.org/10.1680/jstbu.16.00113

[15] Santaphan, S., Baskar, R., 2024. Experimental investigation on cold-formed steel structural frame made with lipped channel column and beam elements subjected to lateral loading. Revista Material. 29(3). DOI: https://doi.org/10.1590/1517-7076-rmat-2024-0323

[16] Lukačević, L., Krolo, P., Bakran, A., et al., 2023. Performance of novel U-connector in CFS truss-to-column bolted connection under axial force. Buildings. 13(7), 1623. DOI: https://doi.org/10.3390/buildings13071623

[17] Tam, P.H., Mohd Sani, M.S.H., Tan, C.S., et al., 2015. Force and Deformation Behaviour of Roof Truss System with Cold-formed Steel Channel Section. In Proceedings of the 9th Asia Pacific Structural Engineering and Construction Conference (APSEC) and 8th ASEAN Civil Engineering Conference (ACEC), Kuala Lumpur, Malaysia, 3–5 November 2015; pp. 180–189.

[18] Mohd Sani, M.S.H., Muftah, F., Tan, C.S., 2018. A state-of-the-art review on cold-formed steel roof truss system. International Journal of Civil Engineering and Technology. 9(9), 746–758.

[19] BS 5950-5:1998. 1998. Structural use of steelwork in building: Code of practice for design of cold-formed thin gauge sections.

[20] BS EN 1993-1-3:2006. 2006. Eurocode 3: Design of Steel Structures—Part 1–3: General Rules–Supplementary Rules for Cold-formed Members and Sheeting.

[21] Yu, C., Schafer, B.W., 2006. Distortional buckling tests on cold-formed steel beams. Journal of Structural Engineering. 132(4). DOI: https://doi.org/10.1061/(ASCE)0733-9445(2006)132:4(515)

[22] Bondok, D., Salim, H., Urgessa, G., 2021. Quasi-static responses and associated failure mechanisms of cold-formed steel roof trusses. Engineering Structures. 231, 111741. DOI: https://doi.org/10.1016/j.engstruct.2020.111741

[23] Wang, W., Roy, K., Rezaeian, H., et al., 2025. Moment capacity of cold-formed steel trusses with Howick Rivet Connectors: Tests, modelling and design. Engineering Structures 322, 119171. DOI: https://doi.org/10.1016/j.engstruct.2024.119171

[24] Dawe, J.L., Liu, Y., Li, J.Y. 2010. Strength and behaviour of cold-formed steel offset trusses. Journal of Constructional Steel Research. 66(4), 556–565.

[25] Reda, M., Sharaf, T., ElSabbagh, A., et al., 2019. Behavior and design for component and system of cold-formed steel roof trusses. Thin-Walled Structures. 135, 21–32. DOI: https://doi.org/10.1016/j.tws.2018.10.038

Downloads

How to Cite

Sani, M. S. H. M., Tan, C. S., & Muftah, F. (2026). Load-Deformation Behaviour of Roof Truss System Made with Cold-Formed Steel Hollow Rectangular Section. Journal of Building Material Science, 8(3), 159–174. https://doi.org/10.30564/jbms.v8i3.13582