2223
-
1961
-
1855
-
1764
-
1609
Bond Behavior between Recycled Concrete Containing CDW and Different Types of Steel Bars
DOI:
https://doi.org/10.30564/jaeser.v4i2.2810Abstract
The operation of reinforced concrete structures is directly associated with the adhesion between the steel bar and the concrete, which allows the internal forces to be transferred to the reinforcement during the process of loading the structural elements. The modification of the concrete composition, with the introduction of recycled aggregate from construction and demolition waste (CDW), affects the steel-concrete interface and can modify the bonding stress, which is also influenced by the type and diameter of the bar used. In this work, the influence of the recycled fine aggregate (RFA) and types of steel bar on the steel-concrete bond was experimentally evaluated using the pullout test. Conventional concrete and recycled concrete, with RFA replacement level of 25%, were produced. Two types of steel rebars (i.e.,plain and deformed) with diameters of 10.0 and 16.0 mm were considered in this paper. The results indicate a reduction in the adhesion stress with the introduction of recycled aggregate, but this trend is influenced by the diameter of the bar used. The use of ribbed bars modifies the stress bonslip behavior, with an increase in the average bond strength, which is also observed with the reduction of the diameter of the bar.
Keywords:
Construction and Demolition Waste (CDW); Recycled concrete; Steel-concrete bond behaviorReferences
[1] Li, X. Recycling and reuse of waste concrete in china. Part II. Structural behaviour of recycled aggregate concrete and engineering applications. Resources, Conservation and Recycling, 2009, 53 (3):107-112.
[2] Etxeberria, M., Mari, A. and Vázquez E. Recycled aggregate concrete as structural material. Materials and Structures, 2007, 40: 529-541.
[3] Fonteboa, B.G. and Abella, F.M. Shear strength of recycled concrete beams. Construction and Building Materials, 2007, 21 (4): 887-893.
[4] Larrañaga, M. E., Experimental study on microstructure and strutural behaviour of recycled aggregate concrete. Doctoral thesis. Universitat Politécnica de Catalunya. Barcelona, 2004. 223p.
[5] Carneiro, J. A., Lima, P. R. L., Leite, M. B., & Toledo Filho, R. D. Compressive stress–strain behavior of steel fiber reinforced-recycled aggregate concrete. Cement and concrete composites, 2014, 46: 65-72.
[6] Lima, P.R.L., Souza, T.S. Avaliação numérica e experimental do modo I de fratura de concreto reciclado. Revista Portuguesa de Engenharia de Estruturas, 2012, Serie II(12): 5-16.
[7] Evangelista L and Brito J. Concrete with fine recycled aggregates: a review. European Journal of Environmental and Civil Engineering, 2012, 18(2): 129- 172.
[8] Mukai, T. and Kikuchi, M., ´Properties of reinforced concrete beams consisting recycled aggregate. Reuse of demolition waste´ In Proceedings of the second international Rilem symposium on demolition and reuse of concrete and masonry, Tokyo, Japan, 1988, pp.670-679.
[9] Xiao, J. and Falkner, H., Bond behavior between recycled aggregate concrete and steel rebars. Construction and Building Materials, 2007, 21: 395-401.
[10] Ajdukiewicz, A. and Kliszczewicz, A. Infuence of recycled aggregates on mechanical properties of HS/ HPC, Cement and Concrete Composites, 2002, 24 (2): 269-279.
[11] Choi, H.B. and Kang, K.I., Bond behaviour of deformed bars embedded in RAC, Magazine of Concrete Research, 2008, 60 (6): 399-410.
[12] ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. NBR ISO 6892. Materiais metálicos-ensaio de tração à temperatura ambiente. 2002.
[13] Reis, C.N.S. INFLUÊNCIA DA UTILIZAÇÃO DE AGREGADO MIÚDO DE RCD NA ADERÊNCIA AÇO-CONCRETO RECICLADO. Dissertação (Mestrado em Engenharia), Feira de Santana, 2009.
[14] RILEM/FIP/CEB, Essai portant sur l’adhérence des armatures du béton. 1. Essai par flexion (7-II-28D). 2. Essai par tration (7-II-128), Recomamdations Provisoires. Matériaux et Constructions, 1973, 6(32): 96- 105.
[15] L. Evangelista a, J. de Brito. Mechanical behaviour of concrete made with fine recycled concrete aggregates. Cement & Concrete Composites, 2007, 29: 397-401.
[16] Poon CS, Shui ZH, Lam L, Fok H, Kou SC. Influence of moisture states of natural and recycled aggregates on the slump and compressive strength of concrete. Cement and Concrete Research, 2004, 34: 31-6.
[17] Barra de Oliveira M, Vasquez E. The influence of retained moisture in aggregates from recycling on the properties of new hardened concrete. Waste Management, 1996, 16:113-7.
[18] Hong, S., & Park, S. K. Uniaxial bond stress-slip relationship of reinforcing bars in concrete. Advances in Materials Science and Engineering, 2012.
[19] COMITE EURO-INTERNACIONAL DU BETON. Bond action bond behaviour of reinforcement, Paris, Bulletin d’Information151. 1982.
[20] Bastwadkar, K. K., & Kulkarni, K. S. Effect of Embedded Length and Bar Diameter of Reinforcement on Bond Strength Behavior of High Strength Concrete Subjected to Elevated Temperatures. Civil and Environmental Research, 2016, 8(1): 50-56.
[21] S. Goudar, B. Das, and S. Arya, "Microstructural Study of Steel-Concrete Interface and Its Influence on Bond Strength of Reinforced Concrete. Advances in Civil Engineering Materials, 2019, 8(1): 171-189.
[22] Angst, U. M., Geiker, M. R., Michel, A., Gehlen, C., Wong, H., Isgor, O. B., ... & Buenfeld, N. The steel– concrete interface. Materials and Structures, 2017, 50(2), 143.